Aktif SCK Series compact substations (E-House) are manufactured for power distribution, oil and gas applications in the hazardous area class (Zone2) according to the IEC 62271-202 standard. It can be equipped with special operation and security systems for hard climatic conditions. SCK Series compact substations are manufactured in three different types according to the material used:

  • SCK-1 : Steel sheet
  • SCK-2 : Sandwich Panel
  • SCK-3 : Container

SCK Series has a compartmentalized design for MV and/or Switchgear, Transformer, Emergency Supply and Batteries in sizes and features appropriate to the need. In addition, it is equipped with a heating/cooling system, fire and smoke detection system, fire extinguishing system, communication system, interior and exterior lighting, grounding and floor insulation as required.

Thermal insulation is provided by using glass or stock wool between the walls of compact transformer substations which can be manufactured in different thicknesses depending on the project requirements. SCK Series compact substations can be designed as skid type or mobile on semi-trailers up to IP54 protection class.

Aktif has ISO 9001, ISO 14001 and ISO 45001 quality certificates.

The following advantages are offered with Aktif SCK Series compact substations:

  • Modular design in requested depth, width and length,
  • High operational safety,
  • Easy transport and commissioning,
  • Internal arc classification in accordance with IAC A and B,
  • Protection class options up to IP54,
  • Safe and tested earthing circuits,
  • Special manufacturing solutions for special projects and different marketing needs
  • Strong construction by made of galvanized sheet steel and painted with electrostatic powder coat,
  • Strong frame by made of hot-dip galvanized steel against to corrosion and NPU base profiles,
  • Door design that can be opened 120 ° outside and against 20 J mechanical impact,
  • Rain channel door design against rain,
  • Natural ventilation or fan and air conditioner option according to the project,
  • Fire detection and extinguishing systems option,
  • Ex-proof equipment option against fire,
  • Solutions for mobile applications on trailers, skids and trailers,
  • Design suitable for use of all types of MV switchgears and LV panels,

Application Areas

  • Rolling Mills
  • Pipelines
  • Industry
  • Shipyards
  • Emergency and Backup Power Facilities
  • Mining
  • Transportation
  • Infrastructure
  • Ambient temperature: -5 ... +50 °C
  • Flammability Class: E
  • Dangerous area class: Zone2
  • Earthquake resistance: 0.5g horizontal and vertical
  • Standard: IEC 62271-202
  • IAC A and B
  • Up to IP54
Type Size Download Link
SCK - Compact Substations E-House PDF 1 MB Download

What are the wall thicknesses of SCK-1, SCK-2 and SCK-3?


for SCK - 1 is 43 mm
Thickness of rock wool / fiber glass wool : 40 mm
Thickness of exterier wall : 2 mm
Thickness of interier wall : 1 mm


for SCK - 2 is 40 mm
Thickness of rock wool / fiber glass wool : 38.9 mm
Thickness of exterier wall : 0.6 mm
Thickness of interier wall : 0.5 mm


for SCK - 3 is 52.4 mm
Thickness of rock wool / fiber glass wool : 50 mm
Thickness of exterier wall : 1.2 mm
Thickness of interier wall : 1.2 mm

×