Switchgear and Substations
SME series Metal Enclosed Modular Switchgears are manufactured in conformity with IEC 62271-200 standard and rated up to 40,5 kV, 1250 A, 25 kA/1s electrical values with LSC-2A service Continuity, Partition class PI, AFL Internal Arc Classification, IP 3X Protection ...
Metal Clad Switchgears are manufactured in conformity with IEC 62271-200 standards and rated up to 40,5 kV, 4000 A, 40 kA/3s electrical values with LSC-2B service Continuity, Partition class PM, AFLR Internal Arc Classification, IP 4X Protection class and with 4/5 independable ...
Mobile substations are electrical systems that flexibly meet energy needs over portable systems. Mobile substations are a good option, especially in rural or isolated areas where electricity is difficult to access. These systems offer an economical solution for ...
Compact substations are secondary transformer systems used in the distribution of energy for low voltage and medium voltage systems. Thanks to compact substation, energy can be distributed more reliably, thus these transformers have spread rapidly due to their high ...
Power Resistors
“Neutral grounding (earthing) resistors” which are connected to the neutral points of power transformers and generators on LV and MV distribution networks used for limiting, measuring and monitoring phase to ground fault current, are manufactured with high technology.
Neutral ...
Load banks are used for performance tests of generators, UPS, voltage regulators, power transformers, alternators and test laboratories and also ensure to operate the generators safely. Aktif manufactures all type of load banks with the required characteristics (R, ...
“Harmonic filter and damping resistors” which are manufactured by Aktif are used to attenuate the harmonics in the networks in a safely and controlled manner. Discharge resistors and RC filters prevent to transient and dangerous discharges caused by inductive loads ...
“Motor control and current limiting resistors” are used for start of rotor-wound, squirrel-cage and induction motors to limit the high starting currents. Current limiting resistors are also used to adjust the current to the desired value at power laboratories and some ...
Power Quality & Power Factor Correction
Aktif low voltage capacitor banks are
designed, manufactured and adapted to
the specific needs of each client. There
are thousands of references around
the world. It has modular and compact
design optimized for easy future
...
MV Power Factor Correction - Capacitor & Filter Banks are
designed, manufactured and adapted
to the specific needs of each client. A
high quality intelligent design brings
advantages to your project from the
start. It has modular and compact
design optimized ...
Asset Low Voltage and High voltage capacitors and reactors are designed and manufactured for Power Factor Correction systems and conventional compensation systems. These capacitors and reactors are presents for all users, suitable safety, long life and high technical ...
Asset Thymod Static Electronic Switch is the electronic switching unit that allows switching the capacitor banks without any discharge delay in the plants and also switching the capacitor banks according to load variation cannot be possible.
Asset Thymod Static Electronic ...
Medical Power & Control Panels
Asset OCP Series Operating Theatre Control Panels are contemporary
and reliable devices, designed for maintaining the most
comfortable environment possible both for patient and
surgery team and the most suitable working conditions
required in the ...
Medical locations are divided in 3 categories in terms of electrical standards; group 0, group 1 and group 2 rooms. Classification of a medical place is related to type of contact with the patient and the purpose of use. Isolated power panel installed as per IEC ...
Medical Isolation Transformers are designed compatible with IEC 60364-7-710 standards for power supply of single phase IT systems and produced in accordance with EN 61558-2-15 standards.
Medical isolating transformers designed at 6 different power stages between 3,15...10 ...
Transfer relays are used for transfering power source between two independent sources in order to provide continuous energy flow for critical loads.
Generally, independent sources are uninterruptable power source (UPS) and mains power. In normal operation, critical ...
Smart Grid
The basics of the energy management system are based on measurement, monitoring, control, and estimation. The term Energy Management System can be defined as a computer system which is designed specifically for the automated control and monitoring of the heating, ventilation ...
Submetering can be defined as reading energy meters, creating invoices and generating reports from the created invoices and read data.
Nowadays, special invoicing applications are needed for organized industrial zones, shopping centers, business centers, residence ...
The first step of the efficiency and continuity is monitoring the quantity and quality of the used energy. While monitoring your consumption and quality with our power and energy measurement devices such as energy analyzers, energy meters, and energy quality analyzer, ...
Why are protection devices important? Each system supplied with electricity has risk and should be controlled continuously and intervened in short periods of time when an emergency, unexpected situation occurs. In this respect, protection devices are important.
Unexpected ...
Traction Substation
Air cooled Diode Coet Traction Rectifiers is designed for Train Lines, Metro Lines and Tram Lines. The range is completed with complete line of inverters and bidirectional converters, using thyristor, IGBT or GTO, to comply with the recent requests of braking energy ...
In the mass production the DC Switchgear is conforming the IEC standards as well as conforming other standards if required.
For the security reason, LBR DC Negative Panels have an grounding position visible from outdoor and lockable for negative maintanence at the Substations ...
In DC Traction applications one disconnect or load break switch normally installed downstream each High Speed Circuit Breakers, and for the security reasons one motorized load break switch installed as parallel.
To comply with these requirements Coet LBD DC Disconnecting ...
TESAR has been designing and manufacturing Cast Resin Transformers for more than 30 years. TESAR transformers are designed and manufactured in conformity to E2 C2 F1 classes in accordance with IEC 60076-11 standards. During its 30 years of activities, TESAR has ...