Aktif CT-1, CTA-1 Series

CT-1, CTA-1 series toroidal current transformers, which are selected according to the cable or busbar thickness, are connected to the current measurement input of the residual current relays and are used to measure the leakage currents.

As a current measurement technique, the currents passing through the phase and neutral lines are collected as vectors and compared with the current value set on the RCR and ELR series relay. In addition to the CT series Toroidal residual current transformers, which are generally used during the cabling or by disconnecting the line connection, installation can be made without disturbing the continuity of the system with the split core type CTA series Toroidal Residual Current Transformer, which is easier to use.

It is known well for the following advantages:

  • Fixed (Solid Core CT Series) or openable (Split Core CTA Series) models
  • Solution for large cable cross-sections
  • Test windings – the control circuit pair (terminals 3-4)
  • There are two windings on Toroidal Current Transformers. One is used to measure the amount of leakage current, while the other is used for the test function on RCR and ELR type residual current relays.
  • By giving a testing current from an external point, both the relay and the transformer can be tested and checked for malfunction.
  • Toroidal Current Transformers are used in electrical panels with high power and thickwire and busbars.
  • With the CTA-1 series split core type transformers, fast and easy installation and maintenance is ensured at points where system downtime would cause great financial damage, such as factories that manufacture in large numbers.

Features of Toroidal Residual Current Transformers

CT-1S external adder type current transformers can be used for higher diameters, .

CT, CTD, CTA CT-1/22 CT-1/35 CT-1/60 CT-1/80 CT-1/110 CT-1/160 CT-1/210 CT-1/300 CTA-1/110 CTA-1/160 CTA-1/210 CTA-1/300
Minimum Measured Current 25 mA 25 mA 25 mA 100 mA 250 mA 250 mA 250 mA 500 mA 250 mA 500 mA 500 mA 1A
Application ELR/RCR Series
Operating Temperature -10÷70 °C
Storage Temperature -20÷80 °C
Transformation Ratio 500/1
Insulation Test 2,5kV for 1 minute
Permanent Overload 1000A
Thermal Overload 40kA for 1 second
Type of Terminal screws with maximum cross section 2,5mm2
Degree of Protection IP20
Standards CEI-EN 500081-2, CEI-EN 50082-2, CEI 41.1, CEI-EN 60255
CEI EN 60947-2 Ek M
CE

Types of Toroidal Current Transformers

CT-1 Series : Fixed Type (Solid Core) Toroidal Current Transformers

Type Diameter (mm) A B C D E F G H
CT-1/35 35 100 110 50 47 60 60 43 30
CT-1/60 60 100 110 50 47 60 60 43 30
CT-1/80 80 150 160 50 70 110 110 43 30
CT-1/110 110 150 160 50 70 110 110 43 30
CT-1/160 160 220 236 64 110 156 156 50 34

CTA-1 Series : Openable Type (Split Core) Toroidal Current Transformers

CTA-1/110

CTA-1/160

CTA-1/210-300

×